Szafa wolnostojąca RTA

Szafa wolnostojąca RTA

Spawana konstrukcja z demontowalnymi ścianami i panelem tylnym, ?IP 20, ładowność 1200/1500 kg

Wzmocniona konstrukcja

Stal formowana na zimno o grubości 1,3 mm.

Szyna przykręcana w czterech punktach

Stal formowana na zimno o grubości 2,5 mm.

Uchwyty Triton

Just by replacing the plastic inlet (is not part of supply) you can choose classic or half-cylindric lock. Patent: PUV 2013-27443.

Powiększone szyny ramy

Wider rails in the body of a cabinet are intended for an additional installation of 19“ power management panels, which afterwards do not occupy space within the cabinet. Thanks to this smart solution of gripping, it does not block sliding servers even for the 600 mm cabinet type. In addition to this solution the A5 version (at the end of the cabinet code) is characterized by break-out blanking panels for possible cable input and management in between neighbouring cabinets.

Perforowane szyny ramy

Kwadratowe otwory wzdłuż całej długości szyny z oznaczeniem jednostek wysokości umożliwiają montaż akcesoriów.

Laserowe oznaczenia jednostek

19" szyny pionowe (ze stali cynkowanej formowanej na zimno) posiadają oznaczenie wg jednostek montażowych.

Główny punkt uziemienia M8

Zawieszane zawiasy

Standardowe zawiasy można zastąpić wygodną w użyciu wersją zawieszaną

Spawanie

Wszystkie odłączane części spajane zgodnie z odpowiednią normą.

Odcięcie linii kablowych

Duża liczba wejść kablowych umożliwia wygodną instalację kabla.

Zabezpieczenie brzegów

Dołączona osłona o długości 1 m.

800 mm wide cabinets

15U - 47 U height

Flex frame

Cabinets with 800 mm width have system, which allows installation of sliding rails in a span of 19“,21“ and 23“.

Montaż opcjonalnych akcesoriów

RAC-VP-D5x-X1

Poziomy organizer kabli (opcja)

RAX-VP-Vxx-X2

Pionowy organizer kabli w ramie szafy (opcja)

Listwa zasilająca montowana w ramie szafy

Możliwość montażu listwy zasilającej w ramie szafy z wykorzystaniem uchwytów (opcja).

Zwiększona ładowność z 1200 do 1500 kg

19“ rail strength member RAX-VR-Txx-X2

Close profile - 1,5 mm cold-rolled steel. Increases the loading capacity of the 800 mm width cabinet up to 1500 kg.

Recommended strengthening kit RAX-VR-Txx-Yx

Kit for 800 mm wide cabinets increase cabinet stability and provide cable management.

Warianty produktu

Opis

  • 19" free-standing cabinet with IP20 protection.
  • Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm)
  • Cabinet construction:
    • Welded steel frame with removable side panels
    • Single or double doors in all metal versions, perforated (80 % and 86 % air permeability) or glazed with safety tempered glass 4 mm. They can be on the front or back of the cabinet
    • Preparation for installation of vertical cable management panels and power distribution units, including mounting brackets, to the frame of the cabinet
    • Preparation for joining the cabinets together
    • A5 and A7 version have a breakout cable entries in the frame for the cabling between cabinets
  • The maximum recommended load of cabinet is 1200 kg, maximum load of the door is 20 kg.
  • The racks are designed for installation of data and telecommunication equipment and distribution systems
  • The frame of the cabinet and all the removable parts (side and rear covers, doors…) are bonded with patch cables that have to be properly fixed and inserted into connectors throughout the period of use of the cabinet.
  • There is one M8 screw placed on the bottom part of the cabinet to connect the earthing wire.
  • Can be mounted on castors and levelling feet (models A1 and A5)
  • Cable openings covered with breakout-type blanking panels are placed in the top and the bottom part of the cabinet.

Więcej informacji na temat tego kontaktu znajduje się w aplikacji.

WARUNKI EKSPLOATACJI

Środowisko działania:

  • Biuro
  • Szafa nie jest przeznaczona do instalacji na zewnątrz i do instalacji w środowiskach, które mogą wpływać niekorzystnie na funkcjonowanie szafy i zamontowanych wewnątrz urządzeń (np. środowiska z niebezpieczeństwem wybuchu, środowiska o wysokiej wilgotności).

Ochrona przed:

  • Uszkodzeniami mechanicznymi
  • Niewłaściwym użytkowaniem
  • Używaniem szafy do innych celów

Niewłaściwe użytkowanie to w szczególności:

  • Przeładowanie (przekroczenie maksymalnego zalecanego obciążenia)
  • Instalacja urządzeń, które mogą wpływać negatywnie na działanie szafy lub pozostałych zainstalowanych urządzeń
  • Zmiany w konstrukcji szafy

Instalacja szafy

  • W celu zapewnienia maksymalnej ładowności zalecane jest równomierne rozłożenie obciążenia.
  • Szafę należy umieścić na płaskiej powierzchni i wyrównać wszelkie różnice za pomocą nóżek poziomujących.
  • Aby zapobiec wnikaniu pyłu do szafy przez otwory wprowadzające kable, otwory te muszą być uszczelnione za pomocą zaślepki ze szczotką lub ramki do wprowadzania kabli (oba te elementy są zawarte w zestawie).

Ochrona środowiska

  • Wszystkie elementy wykonane są z materiałów nadających się do recyklingu, a po demontażu obudowy, muszą być utylizowane zgodnie z odpowiednimi przepisami.

Certyfikaty i zgodność

  • Ten produkt jest w pełni zgodny z normą ČSN EN 62208 ed 2:2012 (EN 62208:2011).

Do pobrania

Galeria zdjęć